{"id":2975,"date":"2017-04-05T09:27:25","date_gmt":"2017-04-05T07:27:25","guid":{"rendered":"http:\/\/www.checkstar-techblog.it\/errore-p2414-su-mini-r56-one-55kw-n12b14a\/"},"modified":"2024-01-12T14:33:24","modified_gmt":"2024-01-12T13:33:24","slug":"errore-p2414-su-mini-r56-one-55kw-n12b14a","status":"publish","type":"post","link":"https:\/\/www.checkstar-techblog.it\/es\/errore-p2414-su-mini-r56-one-55kw-n12b14a\/","title":{"rendered":"Error P2414 en Mini R56 ONE (55Kw N12B14A)"},"content":{"rendered":"<p>\u00a0<\/p>\n<p>Si el c\u00f3digo de aver\u00eda P2414 est\u00e1 registrado en la memoria de aver\u00edas de la unidad de control del motor, intente borrar la aver\u00eda, compruebe el nivel de aceite del motor y la distancia desde la \u00faltima revisi\u00f3n.<\/p>\n<p>el c\u00f3digo se refiere a un error de lectura de la sonda lambda 1 (antes del catalizador). NB : \u00a0<em>NO<\/em> SUSTITUIR EL COMPONENTE.<\/p>\n<p>Esta lectura puede verse influida por el estado de mantenimiento del veh\u00edculo (filtros, buj\u00edas), pero tambi\u00e9n por los componentes mec\u00e1nicos.<\/p>\n<p>Si tambi\u00e9n aparece el c\u00f3digo P0014 (posici\u00f3n del \u00e1rbol de levas), el c\u00f3digo de la sonda es consecuencia de una sincronizaci\u00f3n incorrecta del motor.<\/p>\n<p>Antes de desmontar el motor para su inspecci\u00f3n y posible sustituci\u00f3n del desfasador o de la cadena de distribuci\u00f3n, recomendamos lavar el circuito de lubricaci\u00f3n y cambiar el aceite.\u00a0<\/p>\n<p>\u00a0<\/p>","protected":false},"excerpt":{"rendered":"<p>\u00a0 Si el c\u00f3digo de aver\u00eda P2414 est\u00e1 registrado en la memoria de aver\u00edas de la unidad de control del motor, intente borrar la aver\u00eda, [...].<\/p>","protected":false},"author":1949,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[292],"acf":[],"featured_image_urls":{},"appp_media":null,"views":1903,"_links":{"self":[{"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/posts\/2975"}],"collection":[{"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/users\/1949"}],"replies":[{"embeddable":true,"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/comments?post=2975"}],"version-history":[{"count":0,"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/posts\/2975\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/media?parent=2975"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/categories?post=2975"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.checkstar-techblog.it\/es\/wp-json\/wp\/v2\/tags?post=2975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}