{"id":6810,"date":"2019-03-19T16:32:21","date_gmt":"2019-03-19T15:32:21","guid":{"rendered":"http:\/\/www.checkstar-techblog.it\/?p=6810"},"modified":"2024-01-19T12:43:52","modified_gmt":"2024-01-19T11:43:52","slug":"procedure-for-diagnosis-anomalies-electrical-capote-mercedes-benz-sl-300-r129","status":"publish","type":"post","link":"https:\/\/www.checkstar-techblog.it\/en\/procedure-for-diagnosis-anomalies-electrical-capote-mercedes-benz-sl-300-r129\/","title":{"rendered":"Mercedes Benz SL 300 (R129) electric soft top fault diagnosis procedure"},"content":{"rendered":"<p>Good morning everyone. Below is the procedure for diagnosing malfunctions in the electric soft top management system fitted to Mercedes Benz SL300 (R129)<\/p>\n<p><strong>Troubleshooting procedure Cabinets:<\/strong><\/p>\n<p>1.locate the diagnostic connector in the bonnet;<\/p>\n<p>2. obtain an electric wire and strip it at both ends;<\/p>\n<p>3. turn the ignition key to ON;<\/p>\n<p>4. jumper pin no. 1 and pin no. 10 in the diagnosis for approx. 4 seconds: when the jumper is removed, the roof button starts flashing<\/p>\n<p>5. count the flashes of the button.<\/p>\n<p>5. repeat the procedure until you find all the errors: you will realise you have found them all because they will then repeat according to the number of flashes.<\/p>\n<p>In most cases, it is precisely these stored errors that cause the soft top to fail. Often, deleting the errors will reset the soft top. To delete errors, proceed as follows:<\/p>\n<p>Jumper #1 and #10 for approx. 4 seconds. Once the flashes have occurred, wait approximately 4 seconds: at this point put one side of the cable to pin no. 10 and the other to earth for approximately 8 seconds;<\/p>\n<p>2 repeat the procedure for all errors present<\/p>\n<p>If the cancellation was successful when you reinsert the cable at pin #1 and #10 the soft top button should only flash once: now test the soft top operation. If the soft top still malfunctions hold the button down for 80 seconds, release it and count the flashes of the warning light.<br \/>\nN.B.: The same applies to roll bar diagnostics, but instead of using pins 1 and 10, use pins 1 and 7.<\/p>\n<p>With the hope that this procedure will be useful to you, we wish you good work.<\/p>\n<p>The MM Checkstar Help Desk Team.<\/p>","protected":false},"excerpt":{"rendered":"<p>Good morning everyone. The following is the procedure for diagnosing the presence of malfunctions in the [...].<\/p>","protected":false},"author":49,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[318],"acf":[],"featured_image_urls":{},"appp_media":null,"views":2491,"_links":{"self":[{"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/posts\/6810"}],"collection":[{"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/users\/49"}],"replies":[{"embeddable":true,"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/comments?post=6810"}],"version-history":[{"count":0,"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/posts\/6810\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/media?parent=6810"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/categories?post=6810"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.checkstar-techblog.it\/en\/wp-json\/wp\/v2\/tags?post=6810"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}